Coleman Powermate 5000 Maxa Er Plus User Manual

Advertising
Coleman Powermate 5000 Maxa Er Plus User Manual

*

Maxa 5000 ER – ELECTRIC GENERATOR Maxa 5000 ER – GROUPE ELECTROGENE Maxa 5000 ER – GENERADOR ELECTRICO. This product is warranted by Coleman Powermate, Inc. Powermate, Inc. Pour trouver votre centre de service le plus proche, composer le NUMERO GRATUIT 1-800-445-1805. MAXA 5000 ER PLUS SHOWN WITH CONTROL PANEL AND WHEEL KIT INSTALLED Coleman Powermate MAXA 5000 WATT Series IPL By Model Number: IPL By Engine Number; ColemanPowermatePM0422505.01,PM0422505.02. MORE PARTS LISTINGS FOR COLEMAN POWERMATE GENERATORS: Typical parts found on this type of equipment.

10 HP Tecumseh engine

Coleman powermate 5000 maxa er plus owner

*

Cast-iron cylinder sleeve

*

Low oil sensor

*

Receptacles on endbell

*

5 gallon plastic fuel tank

A.

120 V, 20 Ampere Duplex Receptacle
This duplex is split so that 20 amps of current may be

drawn from each half of the receptacle. However, total power
drawn must be kept within nameplate ratings. These
receptacles may be used along with the twistlock receptacle
provided the generator is not overloaded.

B.

120/240 V, 20 Ampere Twistlock Receptacle
A maximum of 20 amps may be drawn from the 120/240

volt receptacle, provided it is the only receptacle used.
However, current must be limited to the nameplate rating. If the
120/240 volt receptacle is used along with the 120 volt
receptacle, the total load drawn must not exceed the nameplate
ratings.

C.

Circuit Breakers
The receptacles are protected by an AC circuit breaker. If

the generator is overloaded or an external short circuit occurs,
the circuit breaker will trip. If this occurs, disconnect all
electrical loads and try to determine the cause of the problem
before attempting to use the generator again. If overloading
causes the circuit breaker to trip, reduce the load. NOTE:
Continuous tripping of the circuit breaker may cause
damage to generator or equipment.
The circuit breaker may
be reset by pushing the button of the breaker.

This product is warranted by Coleman Powermate, Inc. to

the original retail consumer against defects in material and
workmanship for a period of one year from the date of retail
purchase and is not transferable. This one year warranty
applies only to products used in consumer applications. If this
generator is used in a commercial application, then the period
of warranty coverage is limited to ninety (90) days from the date
of purchase.

Please complete and return the enclosed Customer

Information Card so that we can reach you in the unlikely event
a safety recall is needed. Return of this card is not required to
validate this warranty.

WHAT IS COVERED: Replacement parts and labor.

WHAT IS NOT COVERED: Transportation charges to

Coleman Powermate, Inc. for defective products.
Transportation charges to consumer for repaired products.
Brushes, fuses, rubber feet, and receptacles. Damages
caused by abuse, accident, improper repair, or failure to
perform normal maintenance. Power units or engines which
are covered exclusively by the warranties of their manufacturer.
Sales outside of the United States or Canada. Any other
expense including consequential damages, incidental
damages, or incidental expenses, including damage to
property. Some states do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation
or exclusion may not apply to you.

IMPLIED WARRANTIES: Any implied warranties, including

Coleman Powermate 5000 Maxa Er Plus Manual

the Implied Warranties of Merchantability and Fitness For A
Particular Purpose, are limited in duration to one (1) year from
the date of retail purchase. Some states do not allow
limitations on how long an implied warranty lasts, so the above
limitation may not apply to you.

HOW TO OBTAIN WARRANTY PERFORMANCE:

Replacement parts and service are available from Coleman
Powermate, Inc. Service Centers. Locate your nearest Service
Center by calling TOLL FREE 1-800-445-1805. In the unlikely
event a Service Center can not be located you may call
Coleman Powermate, Inc. for a return authorization number.
Any unit returned WITHOUT an authorization number will
be refused.

To the extent any provision of this warranty is prohibited by

federal, state, or municipal law, and cannot be preempted, it
shall not be applicable. This warranty gives you specific rights,
and you may also have other rights which vary from state to
state.

Coleman Powermate Maxa 5000 Er Owner'…

2

English

ENDBELL

MAJOR GENERATOR FEATURES

LIMITED WARRANTY

(NOT VALID IN MEXICO)

Advertising
This manual is related to the following products:
Popular Brands
Popular manuals
Advertising

PM0525202.02

Insert
Additif
Adición

Maxa 5000 ER – ELECTRIC GENERATOR

Maxa 5000 ER – GROUPE ELECTROGENE

Maxa 5000 ER – GENERADOR ELECTRICO

IMPORTANT – Please make certain that persons who are to use this equipment thoroughly read and
understand these instructions and any additional instructions provided prior to operation.

IMPORTANT - Prière de vous assurer que les personnes destinées à utiliser cet appareil ont pris soin d'en lire
et d'en comprendre le mode d'emploi ou les directives avant de le mettre en marche.

IMPORTANTE. Asegúrese que las personas que utilizarán este equipo lean y entiendan completamente estas
instrucciones y cualquier instrucción adicional proporcionada antes del funcionamiento.

www.colemanpowermate.com LFL 09/02 0061602

Coleman Maxa 4000 Er Plus Manual

Advertising

Coleman Powermate Maxa 5000

This manual is related to the following products:
Popular Brands

Powermate Maxa 5000 Er Parts

Popular manuals

Comments are closed.