The ZEISS brand stands for superior optical and mechanical components. The ZEISS OPMI LUMERA 300 surgical microscope is no exception. Experience outstanding quality. The assistant's microscope, HD camera and the RESIGHT ® 500 from ZEISS fundus viewing system are fully integrated, regardless of the configuration of the surgical microscope. Zeiss opmi lumera 700 Pdf User Manuals. View online or download Zeiss opmi lumera 700 User Manual.
With the surgical microscope OPMI LUMERA 700, even the finest anatomical details are clearly visible, and the red reflex is high in contrast and stable, thanks to its Stereo Coaxial Illumination (SCI) technology and Carl Zeiss optics.
- Parts
- Videos
- News
DESCRIPTION
Effective and gentle retinal photocoagulation.The VISULAS® 532 is a powerful, diode-pumped solid-state laser. Its built-in thermoelectric cooling system ensures excellent temporal stability of the laser power and thus meets the requirements for reproducible clinical results. The VISULAS 532 is designed in particular for retinal photocoagulation, trabeculoplasty and iridotomy for treatment of glaucoma. The VISULAS 532 with the VITE option is primarily useful for multi-spot panretinal and grid photocoagulation.
FORUMSView All (2)
Ask a New Question0Repliesa year ago | a year agoDSLR camera for Carl Zeiss -OPMI 6-CH Please does any one know the ocular port size for Carl Zeiss -OPMI 6 ch microscope matching for transmission to a HDMI monitor or a projector thanks mikeReply |
-gspooner 2 years ago | 2 years agosafety filter looking for an assembly to replace the physician safety filter, error 23 conditions. Reply |
DOCUMENTS / MANUALSView All
FEATURES
- Gentle laser treatment - The ParFocus™ zoom system delivers a homogeneous, sharply defined and reproducible laser spot on the retina and minimizes heat-related side effects on the patient's cornea
- Significantly reduced treatment times - A linear sequence of up to 12 laser pulses can be triggered at the touch of a button on the slit lamp joystick
- Navigating with fingertip precision - The electronic micromanipulator allows sensitive, synchronous laser beam positioning and slit lamp illumination
- Solid performance in the operating room - A perfect duo together with the OPMI LUMERA® 700 surgical microscope
- True-to-color slit lamp image - The active ClearView™ safety filter not only protects the physician but also provides a true-to-color slit lamp image
SPECIFICATIONS
Zeiss Opmi Lumera 700 Manual
Wavelength | 532 nm |
Laser Type | Ophthalamic |
Height | 150 mm |
Length | 400 mm |
Weight | 14 kg |
Width | 300 mm |
Zeiss Opmi Lumera I
Additional Specifications
Zeiss Lumera 700 Microscopes
Aiming beam: Diode, 620 to 650 nm, adjustable brightness (Max. 1 mW at the cornea)
Rated voltage and frequency: 100 V to 240 V, 50/60 Hz
Pulse duration (single pulse): 10 to 2500 ms, cw
Pulse duration (VITE option): 20 to 50 ms
Pulse interval (single pulse): 100 to 6000 ms
Max. power: 1.5 watts at the cornea
Cooling system: Thermoelectric