04 calibrator and control targets 01 abx pentra 400 calibrator target abx pentra hdl cal 13 Nov 2019 04 calibrator and control targets 01 abx pentra 400 calibrator target abx pentra apo cal 13 Nov 2019 04 calibrator and control targets 03 pentra c400 control target abx pentra. Horiba Medical - ABX Pentra 60Small, Convenient, Bench-Top Analyser with Excellent Analytical Performance for Efficient Patient Care, Highly. More ABX Pentra 60 C+ A Dedicated Workstation for a Powerful Management of your Workflow. More ABX Pentra DF 120 Productivity and reliability. More ABX Pentra DF 120 SPS Evolution Productivity and reliability. More ABX Pentra DX 120 In the heart of hematopoiesis.
- Hematology
- Data management on stand-alone PC.
- Micro-sampling from whole blood (CBC: 30 µL - DIFF: 53 µL).
- Cytochemistry, Impedance (real cell volume measurement) & Optical (analysis of the internal cellular structure by measuring light absorbance) - DHSS* Technology.
- Perfect homogenization of blood samples with reagents - MDSS** Technology.
ABX Pentra 60 C+
- Throughput: Up to 60 samples/hour.
- Reagents: Only 4 onboard reagents and 1 diluent.
- Perfect differentiation of the 5 WBC sub-populations with DHSS* Technology.
- 3 histograms for RBC, BAS/WBC and PLT together with the 5 DIFF Matrix.
- Basophils counted through specific channel.
- High resolution matrix.
* DHSS: Double Hydrodynamic Sequential System
** MDSS: Multi-Distribution Sampling System
Manufactured by HORIBA ABX SAS
Technical
Weight | 77 lbs / 35 kg | ||
Power supply | 100 to 240 V (± 10%) - 50 to 60 Hz | ||
Dimensions | 20.3 x 17.5 x 19 in / 51,5 cm x 44,5 cm x 48 cm | ||
Printer | Laser printer | ||
Throughput | 60 tests/hour | ||
Data management | Color screen: 15 in. monitor (800 x 600px) Windows XP Prof.TM User-defined flagging limits Transmit patient & QC to LIS Uni-directional or bi-directional connection Communication Protocols: ABX / ASTM CD-ROM drive / Floppy disk 2 serial ports minimum USB Keyboard / USB Mouse | ||
Memory | 10,000 results + Graphics | ||
Quality Control Management | 12 selectable QC files XB: 60 Operator selectable batches with statistics (20 samples per batch) Within run Levey-Jennings Graphs | ||
Logs | Reagents, calibration, maintenance, errors, blank cycle |
Samples
60 samples/hour (closed tube) | |
---|---|
Parameters (26) | WBC, NEU# & NEU%, LYM# & LYM%, MON# & MON%, EOS# & EOS%, BAS# & BAS%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, PLT, MPV |
Graphs | High-definition LMNE matrix |
Blood Volume | CBC mode: 30 µL |
Stability | 48 hours post-draw stability |
Operating sample mode | Closed tube |
Identification | Alphanumeric. Bar-code reader (optional) |
Results
Parameters | Precision (%CV) | Linearity |
---|---|---|
WBC | < 2.0 | 0-120 x 10³/µL |
RBC | < 2.0 | 0-8 x 106/µL |
HGB | < 1.0 | 0-24 g/dl |
HCT | < 2.0 | 0-67% |
PLT (whole blood) | < 5.0 | 0-1900 x 10³/µL |
PLT (PLT concentrate) | < 5.0 | 0-2800 x 10³/µL |
- Documents
- Parts
- Videos
- News
DESCRIPTION
Small, Convenient, Bench-Top Analyser with Excellent Analytical Performance for Efficient Patient Care- Highly compact and cost-effective.
- Micro-sampling from whole blood (CBC : 30 µL - DIFF: 53 µL)
- Cytochemistry, Impedance (real cell volume measurement) & Optical (analysis of the internal cellular structure by measuring light absorbance) - DHSS* Technology.
- Perfect homogenization of blood samples with reagents - MDSS** Technology.
FORUMSView All (17)
Ask a New Question5Replies3 years ago | 3 years agoPassword Hello. I need of the technician password to access the technician mode. I will be grateful if someone send me. Thanks. Reply |
-duyenhai 3 years ago | 3 years agoHGB no test My Pentra ES60 does not measure HGB (RBC, WBC, PLT be normal)? Duyen Hai Reply |
0Replies4 years ago | 4 years agomd how to communicate with rs 232 of pentra 60 Reply |
FEATURES
Throughput: Up to 60 samples/hour
Reagents: Only 4 onboard reagents and 1 diluent
Perfect differentiation of the 5 WBC sub-populations with DHSS* Technology
3 histograms for RBC, BAS/WBC and PLT together with the 5 DIFF Matrix.
Basophils counted through specific channel
High resolution matrix includes the determination of 2 additional subpopulations (% and #): Atypical Lymphocytes (ALY) and Large Immature Cells (LIC)
DHSS : Double Hydrodynamic Sequential System (HORIBA Medical Patent) ** MDSS : Multi-Distribution Sampling System (HORIBA Medical Patent) *** RUO parameters (Research Use Only)
SPECIFICATIONS
Weight | 77 lbs |
Additional Specifications
Abx Pentra
Technical
Weight
77 lbs
Power supply
100/240 V - 50/60 Hz - 200 VA.
Dimensions
20 in x 18 in x 19 in.
Printer
dot matrix.
Throughout
60 samples/hour.
Data management
68 331 microprocessor.
4 counting channels (68HC11).
Mono-directional connection.
Memory
Last result.
Screen
16 lines LCD screen.
Samples
60 samples/hour (open tube)
Parameters (24+2)
WBC, RBC, PLT, HB, HCT, MCV, MCHC, MCH, PCT, MPV, PDW, RDW, % and # of LYM, MON, NEU, EOS, BAS, *ALY (# and %), *LIC (# and %).
Graphs
High-definition LMNE matrix
PLT, RBC, WBC/BAS
Volume
CBC mode : 30 µL
DIFF mode : 53 µL
Stability
48 hours
Operating sample mode
Open tube
Identification
Alphanumeric. Bar-code reader (optional)
Flags
46 possible pathologic flags.
* RUO (Research Use Only)